Guidance 4D probe; understand the probe by using the ID code; change the 4D generate signal through the electrical relay to create the 4D probe get the job done Commonly. 4.2.two Main board The principle board could possibly be divided into two components: entrance-close of the most crucial board and back-conclusion of the most crucial board.
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat element login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
Get an entire and extended check out with the anatomical structure by panoramic imaging coupled with velocity indication and forward/backward scan capability creating scanning much easier, smoother plus more controllable.
This handbook might referring to info safeguarded by copyright or patents and isn't going to convey any license underneath the patent rights or copyright of Mindray, or of others. Web site nine: Statement
By continuing your take a look at on our Web site, you happen to be consenting to our use of cookies. Having said that, you are able to change your cookie configurations Anytime. Cookie preference Settle for and Progress
Mindray’s new generation of black & white ultrasound technique, DP-fifty Pro, is provided with advanced imaging systems letting deeper penetration and a lot quicker image acquisition with better resolution.
The chapter provides the tactic to validate principal function and effectiveness of product or service. This is certainly only used for reference, not preventive execution. Function checking and screening of the section shall be completed by Mindray provider engineers plus the user collectively. Web page 66: General Examination
Find out far better diagnostic data by means of prolonged watch in the anatomical framework on all convex probes.
iZoom™ permits correct viewing of image from length iWorks™ Protocol allows standardize workflow and lower exam situations
five.two.three Geometric positioning precision Longitudinal geometric positioning accuracy Check Action: Do adjustments as the best way in screening the most depth. History the distance by 20mm Each and every section over the longitudinal targets line utilizing the measurement caliper; Choose the value with the greatest error (to 20mm), calculate the accuracy using the formula beneath The measurement caliper must be positioned within the higher fringe of the goal, Notice:... Site seventy nine Transverse geometric positioning precision Take a look at Action: Deal with the scan floor with the phantom with drinking water or few gel, gently Get in touch with the probe With all the scan surface Modify the depth, producing the transverse targets for being displayed in the graphic. Adjust the main target place to be posited beside the transverse targets (the typical is just not obvious) Modify parameters like gain, TGC, earning Just about every transverse targets to get Plainly displayed. Web site 80 five.5.two.four Blackout Dp50rb Spot Test Action: Go over the scan area of your phantom with water or few gel, Carefully Make contact with the probe with the scan area Alter the depth in a reduce price, and established the focus at the nearest destination to the scan surface. Lower the worth of parameters like AP, Obtain till the history sound just could be viewed. Web page 81: Program Improve And Upkeep
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Notice: Prior to uploading the log, be sure the ultrasound process has been connected to network, in any other case, the system might alert “could not connect to server” The server (smtp.
Take note: Before inserting the connector into the probe port, inspect the connector pin. When the pin is bent, never use the probe right until it's been inspected / fixed / changed. Installing Peripherals For that models from the supported peripherals, please seek advice from “2.
Immediately after replacing the CPU module, vital file needs to be created once again in accordance with the new MAC tackle and prepared into HDD in the machine. Or else, the configuration functionality in the product are going to be misplaced. After eliminating the CPU module, Remove panhead screws with washers (twelve M3X6) fastened on the key device box, you will take off the board. Webpage 118 Figure eight-29 Disassemble the Control Panel Assembly (1) Hold the higher fringe of control panel assembly, and open up up the user interface. Figure eight-thirty Disassemble the Control Panel Assembly (2) Soon after eliminating one particular countersunk head self-tapping screw PT3X10 preset about the control panel and get out the plug of your keyboard and the principle device connecting cables, you may take away the control panel assembly.
A sensible new condition, Increased mobility and effortless Procedure make DP-fifty compatible for all medical settings.